Equipment Specifications Library
Basic Model Information
-
Manufacturer:Metrotech
-
Model:9890 XT
View Manufacturers View Models
Additional Info
RECEIVER
Receiving Frequencies -
Active: 982 Hz, 9.8 kHz and 82 kHz
Passive: 50/60 Hz and 14-22 kHz
Depth Readout Accuracy: ± 5% + 2" under normal conditions
Distance Sensitive Left/Right Guidance:Included
Real-Time Continuous Gain Adjustment: Included
Manual Gain/Peak Mode: Included
Current Measurement: Included
Backlighting: Included
Battery Type: Six AA Cells
Battery Life: 30 hours continuous use
Battery Check: Continuous Automatic
Operation Temperature: -4º to + 122º F (-20º to + 50º C)
Dimensions: 27" L x 7" W x 9" H (68.6 cm x 17.8 cm x 22.9 cm)
Weight: 5.24 lbs (2.35 kg)
TRANSMITTER
Output Frequency -
Active: 982 Hz, 9.8 kHz and 82 kHz
Optional: Optional 4.8 Hz Fault Locating
Simultaneous Frequency Output: 982 Hz, 9.8 kHz and 82 kHz
Automatic "best" Frequency Selection: Included
Ohm Meter: 0-2 kOhm
Nominal Output Power Conductive Mode: 3 watts
Power Settings: Low, Medium, High
Battery Type: 10 D Cells, Optional Rechargeable NiCd
Battery Life -
Alkaline: 28 to 70 hours
NiCd: 9 to 22 hours
Continuous use depending on power and frequency selection
Battery Check: Automatic at start-up
Operation Temperature: -4º to + 122º F (-20º to + 50º C)
Dimensions: 14.25" L x 9.25" W x 5.25" H (36.2 cm x 23.5 cm x 13.3 cm)
Weight: 8.9 lbs (4 kg)
Receiving Frequencies -
Active: 982 Hz, 9.8 kHz and 82 kHz
Passive: 50/60 Hz and 14-22 kHz
Depth Readout Accuracy: ± 5% + 2" under normal conditions
Distance Sensitive Left/Right Guidance:Included
Real-Time Continuous Gain Adjustment: Included
Manual Gain/Peak Mode: Included
Current Measurement: Included
Backlighting: Included
Battery Type: Six AA Cells
Battery Life: 30 hours continuous use
Battery Check: Continuous Automatic
Operation Temperature: -4º to + 122º F (-20º to + 50º C)
Dimensions: 27" L x 7" W x 9" H (68.6 cm x 17.8 cm x 22.9 cm)
Weight: 5.24 lbs (2.35 kg)
TRANSMITTER
Output Frequency -
Active: 982 Hz, 9.8 kHz and 82 kHz
Optional: Optional 4.8 Hz Fault Locating
Simultaneous Frequency Output: 982 Hz, 9.8 kHz and 82 kHz
Automatic "best" Frequency Selection: Included
Ohm Meter: 0-2 kOhm
Nominal Output Power Conductive Mode: 3 watts
Power Settings: Low, Medium, High
Battery Type: 10 D Cells, Optional Rechargeable NiCd
Battery Life -
Alkaline: 28 to 70 hours
NiCd: 9 to 22 hours
Continuous use depending on power and frequency selection
Battery Check: Automatic at start-up
Operation Temperature: -4º to + 122º F (-20º to + 50º C)
Dimensions: 14.25" L x 9.25" W x 5.25" H (36.2 cm x 23.5 cm x 13.3 cm)
Weight: 8.9 lbs (4 kg)
This information is provided for informational purposes only. HDD Broker LLC cannot warrant the accuracy or completeness of this information. This information is subject to change by the manufacturer. Some specifications may vary by model year.